EATON BRL215CAF EATON BR AFCI CIRCUIT BREAKER
EATON BRL215CAF EATON BR AFCI CIRCUIT BREAKER
Eaton | ID: 443000
Manufacturer Part Number: BRL215CAF
Technical Documents
Specifications
Box Quantity | 10 |
American Recovery and Reinvestment Act (ARRA) Compliant | C |
Amperage Rating | 15 A |
Application | Generation - Conventional Energy - Conventional EnergyOtherGeneration - Renewable Energy - Alternative EnergyMarine Vessels and Equipment - Marine Vessels and Equipment - OtherDatacenters - IT Space: CI and Hyper Converged |
Brand Name | Eaton |
Buy American Act (BAA) Compliant | C |
Catalog Description (MFR) | Eaton BR AFCI circuit breaker, FIRE-GUARD AFCI Combination circuit breaker, 15 A, 10 kAIC, Two-pole, 120 V,120/240 V, BR, Common trip, #14-4 AWG Cu/Al, Type BR Loadcenters |
Catalog_Notes | Combination Fireguard/Arc Fault, Common trip refers to two-pole 240V load application sourced by 120/240V, Independent trip refers to two-pole multi-wire, home run or shared neutral circuits. |
Certifications | UL 1699 |
Compliances | Federal Specifications Classification W-C375 |
Concatenated Invoice Description | BR 2P AFCI, 15A, 120/240V, 10kAIC |
Description | EATON BRL215CAF EATON BR AFCI CIRCUIT BREAKER |
Ean | 4015082692780 |
Interrupt Rating | 10 kA |
Invoice Description (MFR) | BR 2P AFCI, 15A, 120/240V, 10kAIC |
Marketing Message (MFR) | Eaton's residential BR Circuit Breakers are used in load centers, panelboards, or similar devices. They are made for a wide range of applications and include: BR 1" circuit breakers and accessories for BR-style load centers; arc fault circuit interrupters (AFCI); and ground fault circuit interrupters (GFCI). |
Number Of Poles | 2 Pole |
Product Feature | Available in 1" thermal magnetic, AFCI, GFCI, and AF/GF designs., Short-body design maximizes your space inside the loadcenter, creating additional wire-way and gutter space for ease of installation., Added and improved diagnostic trip codes designed for complex occurrences and overloads provide you ease of troubleshooting during maintenance., Easy to read trip codes through improved LEDs and a clear test button increases your troubleshooting efficiency., Improved AFCI and GFCI algorithms significantly reduce nuisance tripping, resulting in less call backs., Ability to reset the breaker in the field and eliminate trip history provides you flexibility and accurate indication of most recent trip during troubleshooting., Lower power consumption allows the circuit breaker to produce less heat in high ambient areas, giving customers in those areas peace of mind and helping to reduce unwanted call backs. |
Product Name | Eaton BR AFCI circuit breaker |
Product Type | AFCI circuit breakers |
Safety Data Sheet (SDS) Flag | N |
Special Features | Combination arc fault |
Standard | UL 1699,Federal Specifications Classification W-C375 |
Stripped Catalog Number | BRL215CAF |
Trip Type | Common trip |
Type | AFCI circuit breakers |
UNSPSC | 39121603 |
Voltage Rating | 120/240V |