EATON CHFP120DF CH DUAL FUNCTION AF/GF BREAKER
EATON CHFP120DF CH DUAL FUNCTION AF/GF BREAKER
Eaton | ID: 443499
Manufacturer Part Number: CHFP120DF
Technical Documents
Specifications
American Recovery and Reinvestment Act (ARRA) Compliant | C |
Amperage Rating | 20 A |
Application | Generation - Renewable Energy - Alternative EnergyGeneration - Conventional Energy - Conventional EnergyDatacenters - IT Space: CI and Hyper ConvergedOtherMarine Vessels and Equipment - Marine Vessels and Equipment - Other |
Brand Name | Eaton |
Buy American Act (BAA) Compliant | C |
Catalog Description (MFR) | Eaton CH arc fault / ground fault circuit breaker, CH Dual Function AF/GF Breaker, 20 A, PON, 10 kAICkAIC, 20 A, 10 kAIC , CH Dual Function AF/GF Breaker, 20 A, PON, 10 kAICkAIC |
Certifications | UL Listed |
Concatenated Invoice Description | CHF 1P 20A DUAL FUNCTION PLUG ON NEUTRAL |
Description | EATON CHFP120DF CH DUAL FUNCTION AF/GF BREAKER |
Ean | 9008790577970 |
Interrupt Rating | 10 kA |
Invoice Description (MFR) | CHF 1P 20A DUAL FUNCTION PLUG ON NEUTRAL |
Marketing Message (MFR) | Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker. |
Number Of Poles | 1 Pole |
Product Feature | GFCI, AFCI: Advanced electronics to reduce unwanted tripping from non-compliant devices. Standard LED indicates one of seven trip codes to simplify circuit diagnostics. Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history. Branch overvoltage protection for sensitive electronics. Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC., GFCI: One pole breakers 15–30A 5mA protection per UL943, Plug-on neutral: Time savings up to 25% per AFCI and GFCI installation Improved wireway access Easier troubleshooting due to less wiring Eliminates unwanted tripping due to loose pigtail connections Limited lifetime warranty on all CH products, One pole breakers 15–30A, Plug-on neutral, Standard LED indicates one of seven trip codes to simplify circuit diagnostics., Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history, Time savings up to 25% per AFCI and GFCI installation, Eliminates unwanted tripping due to loose pigtail connections, Improved wireway access, Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC., Limited lifetime warranty on all CH products |
Product Name | Eaton CH arc fault / ground fault circuit breaker |
Product Type | Arc Fault / Ground Fault Circuit Breakers |
Safety Data Sheet (SDS) Flag | N |
Special Features | Plug-on neutral |
Standard | UL Listed |
Stripped Catalog Number | CHFP120DF |
Type | Arc Fault / Ground Fault Circuit Breakers |
UNSPSC | 39121603 |
Voltage Rating | 120V |